Product Area
FS² CCC
Problem
You encounter a transformation error while retrieving business information.
The root cause is related to the XML tag structure:
<Mitarbeiter>within<Auskunft>
The transformation routine cannot correctly process the provided employee numbers.
Technical details:
Affected transformation routine:
/SHC/IF_TR_GET_COMP_MONMSG_RESThe routine fails when handling inconsistent or incompatible employee count values from SCHUFA data.
Solution Steps
Resolve the issue by applying the appropriate fix based on your system version:
Upgrade to a fixed connector version (recommended):
Use SCHUFA-SAP-Connector version 2.2.000 or higher
The issue is resolved via fix: FSCON-2001
For older versions (2.0.x and 2.1.x):
Apply transport: SPEK974212
Important validation step:
Ensure your system version matches the transport requirements before implementation.
Known Limitations
The fix transport SPEK974212 is not compatible with versions older than 2.0.x.
Applying the transport to unsupported versions may cause inconsistencies or system errors.